transformer inductance
Posted by: Rajesh Sharma
on
As per PI expert transformer leakage inductance calculated is to be chhecked with a inductance meter at 100 khz test freq & 1vpk_pk
What will be the inductance value if the tested on an inductance meter with 1khz test freq & 1vpk_pk
Reply soon
Rajesh Sharma
The leakage inductance should be measurable, and should present an accurate value particularly if The reactance Xl is bigger than the DC resistance of the wire.
Having said that, you can also estimate the leakage inductance by going to the apps tv and seeing the video "Estimating transformer parasitic without an impedance analyzer".