솔루션 찾기 기술 지원

UVLO/OV Parameters

Posted by: sean.walsh on

Hi There,

Why is there both a calculated and actual value given for UVLO and OV when the side bar window for that function is opened?

Thanks

Sean

댓글

Submitted by PI-Spock on 04/10/2012

Which product are you referring to and what application PIExpert or PIXls?

Submitted by sean.walsh on 04/12/2012

PI Expert 8 & TOP271KG

Submitted by PI-Spock on 04/12/2012

Oh I see. You are referring to the UV dialog for TOPSwitch-JX family. The UV On min parameter is the target and the Actual parameter is the expected value based on the standard resistor selected in the box at the bottom right of that dialog. For example change one of these resistors from 2 M-ohms to 2.2 M-ohms say and you'll see that the target value stays the same but the actual value changes.

Submitted by sean.walsh on 04/12/2012

Ok, thanks for your help