解决方案查找器 技術支援

SHield Winding in Forward converter(TFS7707H)

Posted by: Kalpesh Diyora on

Dear,

We need to add shieild winding to get benifit in EMI.

What should be the best position of the shiled winding ?

 

Below are the transformer construction that we have.

Input=38VDC

Output:12V/15A (ETD29 Geomatry)

Construction:

Winding -1 -1st half primary (2Layer)

Isolation TAP

Winding-2 -Secondary (Foil construction-6Turns)

Isolation tap

Winding-3 - 2nd Half primary

Outer Wrap

 

Where should be the start and finish of the shileld?

 

Regars,

Kalpesh

回應

Submitted by PI-NANO on 04/24/2015

Hi,

I am assuming there is typographical error in the input voltage (38VDC instead of 380VDC).

I would place the shiled winding between 1st half of primary and secondary (Connect start of the winding to 380VDC bus and other end of the winding leave it floating).

Regards,

PI-NANO