Solution Finder Get Tech Support

RDR-292 :150 W Power Factor Corrected LLC Power Supply for LED Street Lighting

Posted by: seenuvel_27 on

Hi,
We couldn't get the vendor for the LLC transformer(EEL25.4 core and EEL25 Vertical 3 chamber Bobbin).
Shall we use the below EF25 core and the EF25 3 section horizondal bobbin as a alternate for the LLC transformer?
Kindly suggest.

 

EF25 3 section Horizondal bobbin
-------------------------------------
http://www.pinshine.com/upload/product/20090826165107_link.pdf

 

Thanks,

Srinivasan.

Comments

Submitted by PI-Neela on 02/22/2017

EF25 is a little small and could resutls in higher temp in higher ambient. EEL25 on the RDK292 design has similar thermal issue.

suggest to use ETD34 for integrated magnetics. or for seperated leakage inductor design, try EER28  as main transformer.